Welcome to Air University Central Library and Fazaia Medical College Library. (Sign in with Your email. Your user name is the same as your student ID number or Employee ID number for password, please contact Circulation Staff)

PUMP modulated fiber CHAOS communication With cd (Record no. 14137)

MARC details
040 ## -
-- AUI
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER
Author Mark MUK
100 ## - MAIN ENTRY--AUTHOR
Author Name Mukhtar, Farrukh ( 120833)
245 ## - TITLE STATEMENT
Title PUMP modulated fiber CHAOS communication With cd
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of Publication Islamabad
Name of publisher, distributor, etc. Department of Electrical Engineering ( Air University Main Campus)
Date of publication, distribution, etc. 2014.
300 ## - PHYSICAL DESCRIPTION
Pages xv; 69 p.
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Student Project
100 ## - MAIN ENTRY--AUTHOR
-- 17040
520 ## -
-- Secure communication is the need of the time and chaos, due to its complexity of waveform and long time unpredictability, is used to hide message signal in electrical and optical domain. Optical Chaos can be generated using fiber laser, semiconductor laser and microchip lasers. In this thesis EDFRL parameter optimization and trend analysis has been performed to drive EDFRL into chaos from its other three possible regions of operation i.e. stable, periodic and quasi-periodic. Phase plot direct-observation method has been employed for qualitative validation of existence of chaos and Lyapunov exponents have been calculated for its quantitative measurement. The ability to generate large variety of chaotic sequences from same EDFRL configuration has been demonstrated with 10 sample sets of chaos at higher modulating frequencies. It is shown that modulation index, pump power and cavity gain are required to be increased and cavity loss to be decreased for generating chaos at higher modulating frequency. EDFRL Chaos waveform analysis has been done in a time expanded mode which will help in implementing EDFRL chaos based secure optical communication system. A square modulating signal with varying duty cycle has been successfully tested and found to show 16 times better Lyapunov exponent for a duty cycle of 60% as compared to that of pure sine modulating signal. An intermittency route to chaos in EDFRL is observed for the first time by variation of duty cycle. The capability to generate an infinite number of different chaotic sequences just by electrically changing the harmonic combinations of the modulating waveform is demonstrated and with a better LE than that of sine wave. The electrical flexibility to generate new chaos without optically modifying the cavity enhances the security at the field level where it Pump Modulated Fiber Laser Chaos Communication Pump Modulated Fiber Laser Chaos Communication viii is not easy to optically change the cavity frequently and the number of unknown parameters also increases. The comparative study of degree of security provided by EDFRL and semiconductor lasers based chaos generators is performed by calculating the average of positive Lyapunov Exponent spectrum and semiconductor laser is found to be 10 times better than EDFRL. Similarly within EDFRL, loss modulation scheme based pulsed chaos is better than the nonlinearities based non-pulsed chaos. The synchronisation properties of chaos propagation through a 120 km link with dispersion compensation are studied with lumped and distributed EDFA and distributed amplification is found superior to lumped amplification in terms of Noise Figure. A new hybrid scheme based on polarisation interleaving with unequal channel spacing is proposed which reduces the number of FWM mixing terms falling on allocated DWDM channels from 124 to only 4 and also offsets the impairment made by Raman effect in a 8 channel DWDM chaos scheme.
526 ## -
-- MS
Holdings
Withdrawn status Not for loan Permanent Location Current Location Shelving Location Date acquired Full Call Number Accession No./Barcode Date last seen Koha item type
Weeded Out { Not Available }   Air University Central Library Thesis Repository (5th Floor) Air University Central Library Thesis Repository (5th Floor) Electrical Engineering 05/17/2016 620 MUK MS TH1060 01/11/2017 Thesis
Air University Sector E-9, Islamabad Paksitan
Email: librarian@au.edu.pk  Tel : +0092 51 9262612 Ext: 631